Skip to content
The number one comparison site for certification in the Netherlands

All about VCA

VCA is a certificate for working safely and healthily. It is intended for contractors who do work for clients. VCA is not a legal obligation. Your client can require it, though. The SSVV foundation owns the scheme. There are three levels: VCA*, VCA** and VCA Petrochemie. Your client decides which level you need. Since 1 July 2026 version 2026/6.1 applies. On 24 September 2026 CertificeerWijzer counted 20 certification bodies in the Dutch accreditation register that may certify VCA. For the first VCA* audit a small company needs at least 0.75 day at the office, plus visits to work sites.

On this page
  1. What is VCA?
  2. Levels of VCA and related schemes
  3. Who is VCA for and is it mandatory?
  4. What does VCA require?
  5. Steps and lead time of VCA certification
  6. What does VCA cost?
  7. Transferring to another VCA certification body
  8. Who may certify VCA?
  9. Related standards of VCA

SSVV, the owner of VCA, counts about 15,000 companies with a VCA certificate. But what exactly is VCA, and which level does your company need? After reading this article you will know what VCA is, which level suits your work, what the checklist asks, how long the process takes, what it costs and who may certify VCA.

What is VCA?

VCA stands for Veiligheid, Gezondheid en Milieu Checklist Aannemers, the safety, health and environment checklist for contractors. It is a certificate for contractors who do work for a client. Think of work in factories, on installations, in workshops and at project sites. With the certificate you show that you control the risks of that work. That applies to your own people, to temporary workers and to your subcontractors. VCA originally comes from the petrochemical industry. The scheme is also intended for building, civil engineering, electrical and other technical work, such as scaffolding and insulation.

VCA is not an ISO standard. The Stichting Samenwerken Voor Veiligheid (SSVV), a Dutch foundation, owns the scheme. A committee with representatives from the industries manages the content. The scheme is a checklist of 36 questions, divided over 11 chapters.

Each question states what you must do as a minimum and which documents the auditor wants to see. The version that currently applies is called VCA 2026/6.1. Since 1 July 2026 every audit is against that version, including at companies that were already certified. A certificate is valid for three years, and every year the certification body visits for a surveillance audit.

VCA and ISO 45001 both concern working safely and healthily. ISO 45001 is an international standard for a management system. VCA is a Dutch and Belgian checklist with fixed questions. Who ISO 45001 is intended for is explained at ISO 45001.

VCA has three levels. Each level asks more than the previous one. SSVV also has schemes for employment agencies and clients:

SchemeFor whomWhat you must pass
VCA* (one star) contractors who do the work themselves, without subcontractors all 24 must questions
VCA** (two stars) contractors who also use subcontractors, with a SHE structure all 28 must questions and 4 of the 8 additional questions
VCA Petrochemie contractors in the petrochemical industry all 34 must questions and 1 of the 2 additional questions
VCU employment agencies that place people for high-risk work a checklist of its own
VCO clients that ask their contractors for VCA a checklist of its own
VCA-MAX VCA with the extra Behaviour Module (Module Gedrag) VCA plus the requirements of the module

A must question is a question you always have to pass. Of the additional questions you choose a number. Which question belongs to which level is explained in the VCA requirements.

Which VCA level do you need?

Your client decides whether you need VCA and which level. That is how the scheme puts it. So first ask your client which level they expect, before you start. The scheme does not set a limit on the number of employees.

VCA* is for work without subcontractors. If you do use subcontractors, you need VCA** or VCA Petrochemie. VCA** also requires a SHE structure (safety, health and environment), such as a policy and an organisation for safety. On top of that, VCA Petrochemie sets extra requirements for the petrochemical industry.

A self-employed person without staff cannot get a VCA certificate. If they work for you as a subcontractor, they do need the VOL-VCA diploma.

Who is VCA for and is it mandatory?

VCA is not a legal obligation. You can want it yourself, and your client can require it. Companies obtain it for these reasons:

  • Clients. A client can require VCA in the contract or the tender. If your certificate expires, you may no longer be allowed on the job.
  • Your own safety. You want to be sure yourself that your people work safely. The annual audit keeps that sharp.
  • Working in the chain. A contractor with VCA** assesses its own regular subcontractors on safety. If the subcontractor has VCA itself, that is easy to demonstrate.
  • Safety in construction. Since 1 July 2026, clients that have signed the Governance Code Veiligheid in de Bouw (the governance code for safety in construction) ask for safety culture at level 3. That applies to contracts from €100,000 and companies from five employees. Ordinary VCA does not count as evidence there. VCA-MAX does count, for companies with up to 250 employees. For work for ProRail, VCA-MAX does not count. Larger companies demonstrate it with the Safety Culture Ladder.

VCA diplomas for your employees

Besides the certificate for your company, there are diplomas for individuals. The scheme links the two.

Every operational employee who works for you for longer than three months must have the Basic Safety VCA diploma (B-VCA). Every operational supervisor must have the VOL-VCA diploma. A diploma is valid for ten years. The exam centre records it in the Centraal Diploma Register, the central register of diplomas. If one employee lacks the diploma, you do not meet that must question.

The new version of the scheme does not change anything about the diplomas. A recruitment consultant, the employee of an employment agency who places agency workers, obtains the VIL-VCU diploma.

What does VCA require?

VCA requires that you know and control the risks of your work. The questions cover your policy, risk assessments, training, consultation on the shop floor, inspections, equipment inspections, health and incidents. Each question has hard minimum requirements. For example, for VCA* you hold a toolbox meeting at least four times a year. For VCA** that is ten. What each chapter asks is explained in the VCA requirements. Which documents you need to have ready is explained in the documents for VCA.

Steps and lead time of VCA certification

You start with a baseline assessment using the checklist. Then you put the missing points in place. Your SHE management system, your fixed approach to safety, health and environment, must run for at least three months before the auditor may assess on the shop floor. Between your order and the first audit there are usually three to four months at certification bodies. So request quotes early. The steps and the audit are explained in getting a VCA certificate.

What does VCA cost?

The minimum number of audit days follows from a fixed table from SSVV. The price is that number of days times the day rate of the certification body. The table looks at your level, your number of FTE and the number of work sites where you work at the same time.

Take an installation company with 12 FTE and VCA*. It works at four sites at the same time on average. The first audit takes at least 0.75 day at the office. On top of that come two visits to work sites of a quarter to half a day each. Together that is 1.25 to 1.75 days. At a day rate of €1,000 to €1,800 excluding VAT, that audit costs €1,250 to €3,150. The tables and more examples are in the costs of VCA.

Transferring to another VCA certification body

You can take your VCA certificate to another certification body. You then do not start over. The scheme prescribes that the international rules for transferring apply. What applies to VCA is explained in transferring a VCA certificate.

Who may certify VCA?

A VCA certification body needs two things. The first is a contract with SSVV. The second is an accreditation for VCA from the Dutch accreditation body. That accreditation applies per sector code (IAF code). So the sector of your work determines who may certify you.

On 24 September 2026 CertificeerWijzer counted 20 certification bodies with VCA in their accreditation in the Dutch accreditation register. Those are the same 20 names that SSVV puts on its list of recognised certification bodies. None of the 20 may cover all sectors. This is how many certification bodies may certify VCA in these sectors:

SectorSector codeCertification bodies
Construction, including civil engineering 28 19 of the 20
Machinery and equipment 18 19 of the 20
Transport, storage and communication 31 19 of the 20
Business services 35 18 of the 20
Metal industry 17 17 of the 20
Engineering services 34 17 of the 20
Electrical and optical equipment 19 15 of the 20
Chemical industry 12 5 of the 20

So a construction company or installer has plenty of choice. A contractor in the chemical industry has only five. For comparison: for ISO 45001 CertificeerWijzer counted 12 certification bodies on the same day, including those with a foreign accreditation.

Choosing a VCA certification body

The rules and the calculation table are the same for every certification body. So choose on these points:

  • Sector code. All your activities fall within the accreditation of the certification body.
  • Work sites. The certification body states how many work sites the auditor visits and how long each visit takes.
  • Auditor. The scheme requires a VCA auditor to have at least three years of experience in a high-risk sector. Ask whether they have experience with your type of work.
  • Total over three years. Compare the first audit and the two surveillance audits together.
  • Combination. Do you also have ISO 9001 or ISO 45001? Ask whether the certification body may also cover those for your sector.
  • VCA-MAX. Do you want to add the Behaviour Module? You obtain it from the same certification body as your VCA.

Points to consider that apply to every standard are explained in choosing a certification body. At CertificeerWijzer you request quotes with one request from VCA certification bodies that may cover your sector. You enter your level, your FTE and your work sites once. Then you see the differences side by side.

VCA often sits alongside other certificates. These are the most common:

  • ISO 45001 is the international standard for healthy and safe work. The difference with VCA is explained in what VCA is.
  • ISO 9001 concerns quality management. If you have it alongside VCA, you can combine them at one certification body. That is possible if that certification body may cover both for your sector.
  • Safety Culture Ladder measures safety culture. Construction companies from 250 employees use it to demonstrate the ViA level.

Sources

  1. SSVV, VCA checklist version 2026/6.1 ssvv.nl
  2. SSVV, New version of the VCA scheme ssvv.nl
  3. SSVV, VCA scheme ssvv.nl
  4. SSVV, What scheme management is ssvv.nl
  5. SSVV, Recognised certification bodies ssvv.nl
  6. SSVV, VCA-MAX safety culture combination ssvv.nl
  7. SSVV, VCU scheme ssvv.nl
  8. SSVV, Basic Safety VCA (B-VCA) ssvv.nl
  9. GCVB, Veiligheid in Aanbesteding (ViA, safety in tendering) gc-veiligheid.nl
  10. GCVB, Handreiking Veiligheid in Aanbestedingen (guidance on safety in tenders), version 23 June 2026 gc-veiligheid.nl
  11. RvA, SAP-C007 version 4, accreditation protocol for VCA and VCU rva.nl
  12. RvA, all accredited bodies for ISO/IEC 17021-1 rva.nl
  13. BeSaCC-VCA, VCA info (VCA in Belgium) besacc-vca.be
  14. BeSaCC-VCA, VCA: new version 2026/6.1 published besacc-vca.be
  15. Safety Culture Ladder (NEN), Safety Culture Ladder for ViA/GCVB safetycultureladder.com
  16. NEN, NEN-EN-ISO 45001:2023 nl nen.nl